logo

What are you looking for?

Authorized Testing

  • Authorized Testing
  • Certification Part
  • Reaction to Fire Testing

Reaction to Fire Testing

Overview
  • Type approval & MED approval test
  • MMAF type approval for ship or shipborne articles
  • MLTMA flame resistance test for building finishing materials
  • Fire safety standard of railway vehicle technical standard
  • Fire test in accordance with other international standards
화재반응시험 사진
Test items & Criteria
화재반응시험 시험항목 및 적용기준을 안내하는 표입니다.
Noncombustible materials, semi-nonflammable material, fire retardant material
  • Requirements of flame retardance of building finishing materials and fire-retardant structures according to MMAF
Technical standards for railway vehicles
Fire safety standards
  • Fire safety standards for exterior materials and indoor facilities of railway vehicles according to MMAF
Type Approval & MED Test
  • FTP CODE ANNEX 1 PART 1 Non-Combustibility
  • FTP CODE ANNEX 1 PART 2 Smoke and toxicity
  • FTP CODE ANNEX 1 PART 5 Test for surface flammability
Heat release rate
  • ISO 5660-1 : 2002 Reaction to fire tests-Heat release, smok production and mass loss rate/ Part 1 : Heat release rate(cone calorimeter method)
  • KS F ISO 5660-1 : 2008 Combustion performance test - Heat release rate, smoke generation, mass reduction rate - Part 1: Heat release rate (cone calorimetry)
Smoke density
  • ISO 5659-2 : 2012 Plastics - Smoke generation - Part 2:Determination of optical density by a single - chamber test
  • KS M ISO 5659-2 : 2012 Plastics - Smoke generation - Part 2: Measurement of optical density by single combustion chamber test
  • ASTM E 662 : 2012 Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials
Spread of Flame
  • ISO 5658-2 : 2011 Reaction to fire tests-Spread of flame
  • Par t: 2 Lateral spread on building and transport products in vertical configuration
Gas hazard test
  • KS F 2271 : 2016 Gas hazard test method of building finishing materials
Toxicity index
  • BS 6853 : 1999 Code of practice for fire precautions in the design and construction of passenger carrying trains/Annex B/Determinationof weighted summation of toxic fume, R
Combustion gas analysis
  • ISO 19702 : 2006 Toxicity testing of fire effluents - Guidance for analysis of gases and vapours in fire effluents using FTIR gas analysis
Main testing facilities
  • Non-Combustibility Tester
  • Noxious Gas Analyser
  • Gas Analysis Tester
  • Flame-spread Tester
  • Con Calorimeter Tester
  • Smoke Density Tester
Non-Combustibility Tester 사진